Re: CAN Bus Off problem
- From: Achilles <akhil.misra@xxxxxxxxx>
- Date: Wed, 18 Jul 2007 14:30:46 -0000
Hey...
now, I am not shorting the bus physically. I am using a CAN Stress
tool, to induce the error in the ECU transmission. After sometimes,
the ECU goes into the bus off. And the CANalyzer is in listen mode. I
am observing error frames continously on the CANalyzer trace window. I
am not sure why the error messages should come on bus. When the ECU
goes into Bus Off, I stop all the communication in the software for
1000 ms. And then reinitialize it. So as per my understanding, During
those
1000 ms I should not receive any error frames.....
am I correct ?? or soemthing else is expected ??
On Jul 13, 7:24 pm, Jim Nagy <non...@xxxxxxxxxx> wrote:
In article <1184354948.832180.168...@xxxxxxxxxxxxxxxxxxxxxxxxxxxx>,
Achilles <akhil.mi...@xxxxxxxxx> wrote:
I have set the CANalyzer in listen mode. It is not tranmitting
<snip>
Does it mean, when bus is shorted there will not be any kind of frames
on the Bus?? Not even error frames ???
Yes - if the bus is physically shorted, no signal of any kind can get
through. The CANalyzer sees nothing until you remove the short.
--
Jim Nagy